ReferenceAvailable
Close edges
Enable or disable additional Netgen sizing for closely spaced edges.
Enable or disable additional Netgen sizing for closely spaced edges.
Location
Mesh → Free Tetrahedral → Size → Close edges
Initial value: false.
When false, the close-edge factor is omitted from Netgen so that a stored factor cannot silently enable this sizing rule. When true, Close edge factor controls the rule.
Using the value
Enable it when nearby geometric edges need additional resolution and inspect the resulting mesh.
Troubleshooting
Accepts a boolean value. If changing the factor has no effect, check that Close edges is enabled.