ReferenceAvailable
Close edge factor
Set the Netgen parameter for sizing between close edges.
Set the Netgen parameter for sizing between close edges.
Location
Mesh → Swept / Mapped → Size → Close edge factor
Initial value: 2.
This is a finite positive dimensionless Netgen factor, applied only when Close edges is enabled. It is not a physical gap width. These Netgen controls do not change the supported structured box-meshing path; use its size and through-thickness controls instead.
Using the value
Enable Close edges before adjusting its factor, rebuild, and inspect the actual narrow region.
Troubleshooting
Zero, negative and non-finite values are rejected. A stored factor does not turn on the disabled rule.