Skip to documentation content
On this page
  1. Reference contract
  2. Contract
  3. Authoritative source

Magnetics

Magnetic vector-potential scalar component interface using the differentiable runtime.

Reference contract

FieldValueDescription
constraints[]
coupled_runtimenull
differentiable_runtime{"certification":"MagneticsScalarEllipticRuntime","coordinate_expression_gradient":true,"coordinate_gradient":true,"design_properties":["reluctivity"],"execution_backend":"telion-v2-shared-execution","expression_objectives":true,"material_expression_gradient":true,"material_gradient":true,"objective_rules":[{"entity_dimensions":["global","domain","boundary","point"],"modes":["stationary"],"operators":["integral","average","minimum","maximum","rms","norm","smooth-maximum","smooth-minimum"],"supports_selection":true,"symbols":["mg.Az"],"value_kind":"field"},{"entity_dimensions":["global"],"modes":["stationary"],"operators":["value"],"supports_selection":false,"symbols":["mg.energy"],"value_kind":"scalar-global"},{"entity_dimensions":["global"],"modes":["stationary"],"operators":["value"],"supports_selection":false,"symbols":["mg.compliance"],"value_kind":"scalar-global"}],"residual_owner":"Magnetics.element_residual","state_fields":["Az"],"supported_objective_symbols":{"coordinate":["mg.Az","mg.energy","mg.compliance"],"material":["mg.Az","mg.energy","mg.compliance"],"topology":["mg.Az","mg.energy","mg.compliance"]},"topology_expression_gradient":true}
dynamic_outputs[]
equation_summary-div(nu*grad(Az)) = Jz
frequency_domain_runtimenull
metadata{"releaseSupport":{"certifiedStudies":[],"manifest":"docs/september-2026-classroom-physics-matrix.json","manifestSha256":"8f1273eda113099a6658438b1513d127c2c4c99c511c5a6fc5b82637cf6bc949","profile":"september-2026-classroom","reason":"Magnetics has no certified study in the September 2026 classroom support matrix.","selectable":false}}
preferred_materialnull
schema_version2.0.0
studies[{"certified":false,"differentiability":"exact-ad","kind":"stationary","reason":"Magnetics stationary is outside the September 2026 classroom support matrix."},{"certified":false,"differentiability":"exact-ad","kind":"sensitivity","reason":"Magnetics sensitivity is outside the September 2026 classroom support matrix."},{"certified":false,"differentiability":"exact-ad","kind":"optimization","reason":"Magnetics optimization is outside the September 2026 classroom support matrix."}]
transient_runtimenull
weak_contributions[{"differentiability":"exact-ad","entity_dimension":"domain","expression":"dot(grad(test(mg.Az)), reluctivity*grad(mg.Az)) - test(mg.Az)*currentDensity","name":"mg.vector_potential","test_field":"mg.Az"}]
categoryAC/DC
descriptionMagnetic vector-potential scalar component interface using the differentiable runtime.
dimensions[3]
display_nameMagnetics
kindMagnetics
namespacemg
statusdevelopment
visiblefalse

Magnetic vector-potential scalar component interface using the differentiable runtime.

Contract

PropertyValue
constraints[]
coupled_runtimenull
differentiable_runtime{"certification":"MagneticsScalarEllipticRuntime","coordinate_expression_gradient":true,"coordinate_gradient":true,"design_properties":["reluctivity"],"execution_backend":"telion-v2-shared-execution","expression_objectives":true,"material_expression_gradient":true,"material_gradient":true,"objective_rules":[{"entity_dimensions":["global","domain","boundary","point"],"modes":["stationary"],"operators":["integral","average","minimum","maximum","rms","norm","smooth-maximum","smooth-minimum"],"su...
dynamic_outputs[]
equation_summary-div(nu*grad(Az)) = Jz
frequency_domain_runtimenull
metadata{"releaseSupport":{"certifiedStudies":[],"manifest":"docs/september-2026-classroom-physics-matrix.json","manifestSha256":"8f1273eda113099a6658438b1513d127c2c4c99c511c5a6fc5b82637cf6bc949","profile":"september-2026-classroom","reason":"Magnetics has no certified study in the September 2026 classroom support matrix.","selectable":false}}
preferred_materialnull
schema_version2.0.0
studies[{"certified":false,"differentiability":"exact-ad","kind":"stationary","reason":"Magnetics stationary is outside the September 2026 classroom support matrix."},{"certified":false,"differentiability":"exact-ad","kind":"sensitivity","reason":"Magnetics sensitivity is outside the September 2026 classroom support matrix."},{"certified":false,"differentiability":"exact-ad","kind":"optimization","reason":"Magnetics optimization is outside the September 2026 classroom support matrix."}]
transient_runtimenull
weak_contributions[{"differentiability":"exact-ad","entity_dimension":"domain","expression":"dot(grad(test(mg.Az)), reluctivity*grad(mg.Az)) - test(mg.Az)*currentDensity","name":"mg.vector_potential","test_field":"mg.Az"}]
categoryAC/DC
descriptionMagnetic vector-potential scalar component interface using the differentiable runtime.
dimensions[3]
display_nameMagnetics
kindMagnetics
namespacemg
statusdevelopment
visiblefalse

Authoritative source

Catalog
telion_backend.v2.catalog.PhysicsCatalog
Identity
physics-interface:mg
Path
src/telion_backend/v2/physics
Symbol
PhysicsDeclaration