physics-outputAvailable
Element absorbed reactive power
Publishes Element absorbed reactive power as the `cir.Q(element)` result symbol for Electrical Circuit.
Reference contract
| Field | Value | Description |
|---|---|---|
| unit | var | — |
| rank | scalar | — |
| components | 1 | — |
| location | global | — |
| expression | cir.Q(element) | — |
| studies | ["frequency-domain"] | — |
| differentiability | exact-ad | — |
| plottable | true | — |
| functional_dimensions | ["global","domain","boundary","edge","point"] | — |
| study_overrides | [] | — |
Publishes Element absorbed reactive power as the cir.Q(element) result symbol for Electrical Circuit.
Unit, rank, component count, field location, expression, supported studies, functional dimensions, and study-specific overrides are declaration-owned.